It is currently Tue Jun 24, 2025 5:15 am




Reply to topic  [ 6 posts ] 
 Having Hydro Trim Problem 
Author Message
MMT Member

Joined: Sun Apr 12, 2009 9:45 am
Posts: 3
Location: Wasilla, Alaska
Post Having Hydro Trim Problem
was wondering if others have had there trim on pd not want to lift or just won't?
Fluids are all good and battery is good? What else would be causing this to act up?


Mon Jul 13, 2009 5:28 pm
Profile
MMT F.E.
User avatar

Joined: Tue Mar 10, 2009 8:17 pm
Posts: 785
Location: Meraux, LA
Post Re: Having Hydro Trim Problem
switch might be out

_________________

HRCH Cajun Black "VOODOO" Magic

18x48 Center Console PD w/32PDHydro T&T; Hydro Reverse
"If I wanted any of your lip; I would pull down my zipper"


Mon Jul 13, 2009 5:31 pm
Profile
MMT Elite Member
User avatar

Joined: Tue Jan 13, 2009 6:08 pm
Posts: 5282
Location: Meraux,La.
Post Re: Having Hydro Trim Problem
b bvhiodfnhbgv


Mon Jul 13, 2009 5:40 pm
Profile
MMT Elite Member
User avatar

Joined: Tue Jan 13, 2009 8:02 pm
Posts: 6243
Location: Bossier City
Post Re: Having Hydro Trim Problem

_________________
18x48 Charles Leonard / 36PD

"I do think there is a Squatch in these woods"!!!!!


Mon Jul 13, 2009 5:47 pm
Profile
MMT Elite Member
User avatar

Joined: Tue Jan 13, 2009 6:08 pm
Posts: 5376
Location: Venice, La
Post Re: Having Hydro Trim Problem
We've been haven a few down this way doing exactly what your discribing. Try a little test. tap a screw driver handle on the motor of the pump while triming up or down. if it starts working while your tapping then more than likely you've got water in there causing rust to build up on the armature or the field .

Simple fix, Disconnect the battery, remove the pump from the bracket ( DON'T disconnect the hydraulic lines) 2 small screws hold the pump to the motor. remove them, (motor should seperate from the pump). look and see if you do indeed have water or rust building up. If so theres 2 screws holding the field and armature in place remove them ( I find the screws to be really tight and tend to want to strip out take a small pair of vise grips and us them to break them free). everything should slide out the plastic cover. Clean everything with Elec cleaner, might have to clean the armature and field with a little fine grit sand paper. then clean it again.

reassemble the motor exactly the way you took it apart. ( I reconnected the battery and test ran the motor before reinstalling it to the pump.) if alls well take a little dab of silicone or rtv and seal between the motor and and the pump and where your wires go into the motor housing. you should be good to go. around a 30 min job


Mon Jul 13, 2009 6:13 pm
Profile
MMT Member

Joined: Sun Apr 12, 2009 9:45 am
Posts: 3
Location: Wasilla, Alaska
Post Re: Having Hydro Trim Problem
Thank You!!!!!!

I will try that. It was working just fine and now it wont come up, sounds like something as the rust issue in the armature(sp).

I now that I didn't drain last winter and the last time I used it the temps were around -19 and it was not liking that.
Thanks again!!!


Mon Jul 13, 2009 6:30 pm
Profile
Display posts from previous:  Sort by  