Author |
Message |
darrel from meraux
MMT Addict
Joined: Wed Feb 18, 2009 9:31 pm Posts: 584 Location: Meraux, LA
|
 Floor Material guage
What gauge are you guys using for the aluminum on your floors? I'm almost finished up building my 17x54 and want do weld in some floors. My boat is 54 at bottom with 5 stringers. I don't want to floor to flex, especially enough to bend or sag. I was thinking .100g but my boat builder buddy said he wouldn't touch anything under .125. That just seems like a lot of extra weight if i can get by thinner. I did have an old go-devil boat that when I removed the foam from the floor sagged and flexed bad! But If i remember correctly it was super thin possibly .080. Any help?
_________________ 17x54 custom CC with stage 3 GTR.
|
Mon Jun 16, 2014 10:00 am |
|
 |
cupped up
MMT 1000 Club
Joined: Tue Jun 05, 2012 7:25 pm Posts: 4205 Location: St. Amant, LA
|
 Re: Floor Material guage
The weight difference ain't really significant between 125 and 100, you ain't talking but like 20 lbs or so for a floor sized sheet
|
Mon Jun 16, 2014 10:19 am |
|
 |
darrel from meraux
MMT Addict
Joined: Wed Feb 18, 2009 9:31 pm Posts: 584 Location: Meraux, LA
|
 Re: Floor Material guage
Yea that was my original thought when we built it so I went .125 on everything...console, boxes, catwalks, poling platform, and huge front deck so adding all that weight, safe to assume a few hundred pounds, Im kind of scraping the barrel as far as weight goes. Most likely everyone will say .125 though and ill wind up tacking on a few more pounds lol
_________________ 17x54 custom CC with stage 3 GTR.
|
Mon Jun 16, 2014 10:57 am |
|
 |
BoatDR
MMT Sponsor
Joined: Tue May 24, 2011 6:43 am Posts: 1604
|
 Re: Floor Material guage
Most boat builders put 6 or more stringers in a 54" wide boat. With only 5, you will need to go .125 to keep it from flexing.
|
Mon Jun 16, 2014 11:08 am |
|
 |
banded-mallard
MMT 1000 Club
Joined: Wed Oct 07, 2009 8:18 pm Posts: 4310
|
 Re: Floor Material guage
I used .100 gauge on all my decks, floor and side seat. I built mine with weight in mind. The difference in a 4x12 sheet is 26 lbs. Mine is 17x48 with 5 "hat section" ribs with 3 cross braces that are flush mounted. I went with a 3/16 bottom due to where I hunt. I have no flex in my floor. The .100 gauge is fully welded out and stitched welded every foot to the 5 ribs.
|
Mon Jun 16, 2014 11:23 am |
|
 |
southernfire97
MMT Pro Member
Joined: Sun Feb 12, 2012 7:58 pm Posts: 170 Location: South MS
|
 Re: Floor Material guage
I just put a floor in my war eagle. It's .125 and has zero flex
|
Wed Jun 18, 2014 4:13 pm |
|
 |
fowllife08
MMT 1000 Club
Joined: Sun Sep 18, 2011 7:25 pm Posts: 3676 Location: down in da flats, LA
|
 Re: Floor Material guage
I have .100 and fuck that shit lol.
_________________ 35 GTR chasin a BBC 1848
|
Wed Jun 18, 2014 4:47 pm |
|
 |
darrel from meraux
MMT Addict
Joined: Wed Feb 18, 2009 9:31 pm Posts: 584 Location: Meraux, LA
|
 Re: Floor Material guage
Thanks guys. Went ahead and played it safe and went .125. Easier to weld and like boat dr said no worrying about flex. Thanks for all that replied.
_________________ 17x54 custom CC with stage 3 GTR.
|
Wed Jun 18, 2014 7:17 pm |
|
 |
DuckHunterF250
MMT 1000 Club
Joined: Tue Jun 29, 2010 8:32 pm Posts: 1801 Location: atlanta texas
|
 Re: Floor Material guage
.100 in all mine.
_________________ 1854 DeadFowl custom boat 35 GTR "The bitterness of poor quality remains long after the sweetness of low price is forgotten."
|
Wed Jun 18, 2014 7:24 pm |
|
 |
Woodiebuster
MMT Elite Member
Joined: Wed Mar 03, 2010 7:00 pm Posts: 6060 Location: Choudrant, La
|
 Re: Floor Material guage
I'm prolly going with .080 or thinner
_________________ CSM Custom 18x42 Battleship with a 36 PD beating you to the hole My Rig (Old Motor) viewtopic.php?f=5&t=45193
(New Motor) viewtopic.php?f=5&t=54733 Stumps Fear Me
|
Thu Jun 19, 2014 8:20 am |
|
 |
North LA Hunter
MMT Elite Member
Joined: Mon Aug 02, 2010 8:39 pm Posts: 6976 Location: West Monroe, LA
|
 Re: Floor Material guage
|
Thu Jun 19, 2014 8:21 am |
|
 |
southernfire97
MMT Pro Member
Joined: Sun Feb 12, 2012 7:58 pm Posts: 170 Location: South MS
|
 Re: Floor Material guage
Think he said he already went with .125. IMO anything less than that flexes too much. I hate a floor that flexes. No sense in it.
|
Thu Jun 19, 2014 8:25 am |
|
 |
darrel from meraux
MMT Addict
Joined: Wed Feb 18, 2009 9:31 pm Posts: 584 Location: Meraux, LA
|
 Re: Floor Material guage
yea I went with .125 for my entire full welded in floor going from .100 to .125 was only like 9 lbs difference
_________________ 17x54 custom CC with stage 3 GTR.
|
Thu Jun 19, 2014 10:28 am |
|
 |
schmitt
MMT 1000 Club
Joined: Fri Jun 25, 2010 3:33 pm Posts: 1177 Location: WI
|
 Re: Floor Material guage
_________________ 1848 DeadFowl pushed by a Stage 4 Delta powered MB HDR (JBP dusting)
|
Thu Jun 19, 2014 12:56 pm |
|
 |
|